GW5 Series Outdoor High Voltage Disconnectors
GW5 series Outdoor High Voltage Disconnectors consists of three single phase, V type for each phase, symmetrical angle is 50°.
Description
Description
GW5 series Outdoor High Voltage Disconnectors consists of three single phase, V type for each phase, symmetrical angle is 50°, disconnect switch is made of pedestal, post insulator and electric part. They are used in no-load condition to switch off the electric circuit and isolate electrical equipment, such as high voltage bus, circuit breaker etc, and high voltage line up to 252kV power system.
GW5-40.5/72.5/126/252 outdoor high voltage disconnecting switch is used to make or break high voltage circuit in rated voltage 40.5kV, 72.5kV, 126, 252kV, AC 50/60Hz electric system. It can open and close small capacitance and inductive current. This disconnecting switch accords with standards: IEC62271-103 High voltage switches. GB1985: AC High voltage disconnect switch and earthing switch and IEC 60694 & GB/T11022: Common technical requirements of HV switchgear and control equipment.
Environment condition
– Ambient temperature: max +40°C min -25°C
– Altitude: ≤1000m
– Wind pressure: ≤700Pa (equals to wind speed 34m/s)
– Air contamination degree: IV degree
– Earthquake intensity: ≤8 degree
– No corrosive or flammable gas, no frequent violent vibration
Technical Data
1 | Rated Voltage (kV) | 40.5 | 126 | 252 | ||||||||
2 | 1min power frequency withstand voltage (Effective value) kV | To Ground | 95 | 230 | 460 | |||||||
Between Fracture | 115 | 245 | 460+145 | |||||||||
3 | Lightning Impulse withstand voltage (Peak value) kV | To Ground | 185 | 550 | 1050 | |||||||
Between Fracture | 215 | 630 | 1050+200 | |||||||||
4 | Mechanical life (Times) | 2000 | ||||||||||
5 | Rated Current (A) | 630 | 1250 | 1600 | 2000 | |||||||
6 | Rated short time withstand Current (kA) | 20 | 31.5 | 40 | 40 | |||||||
7 | Rated withstand current (Peak value) kA | 50 | 80 | 100 | 100 | |||||||
8 | Rated connect machine load (N) | Horizontal vertical | 750 | 1000 | ||||||||
Horizontal transverse | 500 | 750 | ||||||||||
Vertical force | 750 | 1000 | ||||||||||
9 | Creepage distance (mm) | 1013-2256 | 1813-2250 | 3150-3906 | ||||||||
10 | Manual operating mechanism | Model | CS17, CS17G | |||||||||
Control loop voltage (V) | AC220, DC110, DC220 | |||||||||||
11 | Motor operating mechanism | Model | CJ6 | |||||||||
Motor voltage (V) | AC220, AC380, DC220 | |||||||||||
Control loop voltage(V) | AC220, AC380, DC220 | |||||||||||
Switching time (s) | 6±1 |
Outline & Mounting Dimensions
1.Connector base 2. Main contact 3. Main touch finger 4. Connector base
5. Contact touch finger 6. Post insulator 7. Limit plate 8. Earthing knife
Reviews